J. Nelson Residence





SM08
J. Nelson Residence
Please login or register to view address information

Printer Friendly Info

A 6 module, 1.344 KW PV system. This was a good application for Enphase micro-inverters because a shadow from the 8" furnace exhaust vent passes across two of the modules during the morning. Since there is a separate inverter associated with each module, only the shaded module's production is affected when the shadow falls on it. Had we used a traditional "string" inverter instead of six micro-inverters, production by every module would have been affected even though the shadow may be cast on only one module.



System Components
solar electric

6 Sharp 224 watt modules

6 Enphase micro-inverters

Homeowner uses Enphase's Envoy monitoring system.


System Designer: Charlie Pickard
System Engineer: Charlie Pickard
System Installer: Aladdin Solar

Date of Installation Completion: July, 2010

Anticipated Energy Delivery When Purchased

1400 KWH per year