This is a conventional frame house, fortunate enough to be oriented with the long side facing south.  Much of our south roof and walls are covered with collectors of different types and ages.  The first system was installed in 2004.

Our home produces 3 types of solar energy:  1) Roof mounted solar hot water  2) Roof mounted solar electric,  1.92 KW, grid tied  3) Wall mounted solar air heat collectors (for space heating).  



System Components
solar electric solar hot water solar heat
Electric:  16 Kyocera 120 watt modules/Fronius IG 2000 inverter
Hot Water:  2 - 3' X 6' AAA Solar collectors, drainback system
Heat:  (Newest collector) RREAL's SPF40 Solar Powered Furnace

Hot water system:  Drain back system.  Preheats the water going into the electric water heater

There are 3 hot air collectors:  one home made, one rebuilt, and one brand new Solar Powered Furnace (SPF) locally manufactured in Pine River.


System Designer: Joel Lindstrom, owner
System Installer: Joel Lindstrom and RREAL (Rural Renewable Energy Alliance)

Date of Installation Completion: June 5, 2004 for Electric and Hot Water April 2010 for SPF

Anticipated Energy Delivery When Purchased

1964 KWH per year (calculated on 12-23-06)


Actual Energy Delivered When Installed
Actual Energy Delivered:  2144 KWH per year average
          2005    2099 KWH
          2006    2163
          2007    2127
          2008    2224
          2009    2106    
                    10,719 KWH / 5 = 2144 average KWH/yr.

Percentage of Total Energy Needs Delivered:

50% of electric only.  2009: produced 2106 KWH, consumed 4230 KWH (Data system not available to calculate energy delivery for hot water or heat, will know fuel savings for new SPF in a year.)